SuperEndo Endodontic Bur Kit has several types of burs used to accomplish good access cavity preparation prior to endodontic treatment.The set consists of 7 types of burs (E-014LC, ENDO Z, 697-014M, E-012C, 697-017M, E-016C and E-018C).These are instrumental in creating the initial access,removal of carious dentin,removal of unsupported enamel,creating a flat floor,removal of the roof of pulp chamber,creating a proper outline form of the access cavity.
Efficient
Precision and Smooth Cutting Burs
Diamond Burs with varying coarseness
Produces less heat
Autoclavable
Package Dimensions : 9.4 x 3.5 x 2.4 inches
Set of 8 Burs
E-012C
E-016C
697-017M
E-014LC
697-014M
801-016
ENDO Z
E-018C
Insert the instrument as deeply as possible into the chuck (Friction Grip).
Set the handpiece at the required working speed before applying the instrument to the treated area.
Apply a maximum operating force of 0.4 [N] and do not exceed a speed of 230’000 [rpm].
Activate water spray during the entire treatment (minimum 50 mL/min).
Regulate water flow in case of water excess or shortage.
It is recommended to use a dental dam.
Use the instruments over the entire length of their working part and not just at the tip, so as to avoid an unconscious increase of the contact pressure causing local overheating.
Once the preparation has been completed, remove the instrument from the site and allow it to come to a standstill.
It is recommended to wear gloves and safety glasses.
Yes, the SuperEndo Endodontic Bur Kit can be used with a push-type Waldent airotor. The burs in this kit are designed for endodontic procedures and are compatible with airotors.
The SuperEndo Endodontic Bur Kit is specifically designed to be used with airotors only and is not recommended for use with contra-angle handpieces or micromotors.
Check for possible damages; dispose of oxydized, blunt and eccentric instruments. Dispose of tungsten carbide instruments with fractured and incorrectly shaped blades.
Use only cleaning/disinfection solutions that provide corrosion protection. In case of tungsten carbide instruments, avoid contact with H2O3 (hydrogen peroxide). It attacks and damages tungsten carbide. Use a single-pulsed or fractionated vacuum autoclave and subvacuum drying. Chemiclave sterilizers may also be used.
Avoid jamming or levering actions when rotating, as this increases the risk of instrument breakage. Never exceed the specified maximum speed. Avoid applying forces greater than the recommended values, as this could cause damage to the instrument and the treated area. Always Check for possible damages; dispose of oxydized, blunt and eccentric instruments.